Inverters
UPS
LPG Gas Gysers
RO Systems
Stabilisers
Radient Heaters
Batteries
 
Home
 
 
  Batteries
 

Source of Dependable Power

   
 

INTRODUCTION

  VOYAGER Inverter Batteries are dependable source of Power back-up ideally suited for extreme environmental and erratic power conditions. From state of the art manufacturing facility, these batteries are designed to deliver top performance and long life.

 

 
  Features :
 

Safety Vent plugs
Specially designed to eliminate acid loss in the cell

Corrosion Resistance Terminal Post.
Heavy-duty terminal post improves current flow

Durable polypropylene Cell Container.
Impact resistance Container to house negative & positive cells.

Intercell  Connections
Spot-welded to increase current flow.

Negative Plates.
Latest computer designed grid to enhance optimum utilization of active materials thereby increase performance.

PVC/Glass Mate Separator
Low electrical resistance PVC separator to eliminate internal short-circuit and allow better circulation of electrolyte & glass mate reduces top-up requirement of electrolyte.

 
  Applications :
UPS Systems

Emergency Lighting

Inverters

Switchgear Operation in Substations

EPABX

Alarm Systems

Genset Starting Operations

 
  TECHNICAL SPECIFICATIONS
 
Model Voltage
(Volts)
Capacity Dimensions (mm) Dry
Weight(Kgs)
Appp.Acid
Volume(ltr)
Ah Length Width Height
N-150 12 135 516 272 240 31.5 18
N-165 12 150 516 272 240 33 17
N-200 12 180 516 272 240 36 15
N-1500 12 150 516 272 240 32 17
 
   

NORMAL RECHARGE

Constant Voltage Charging is recommended for maintaining the battery in fully charged state.

Recommended Charging Voltage is 13.8~14.2 V.

The charging current should be maintained as given below

   

BATTERY MAINTENANCE

Electrolyte level should be checked after every 2 months. The required water topping-up-frequency is 4 months under ideal conditions.

Only distilled water/de-ionized water should be used for topping-up the battery. Tap water/mineral water/acid filling can damage the battery plates.

If a wet charged battery is stored, additional charge is required after every 15 days.

If a wet battery is transported, following precautions must be taken:

 
  • Ensure the battery vent-plugs are proper tightened.
  • Ensure no over filling.
  • Battery to be upright with terminal facing-up.

General life expectation of battery under ideal condition 2-3 years.It is highly dependent factors:

 
  • Application
  • Operating Temperature
  • Depth of Discharge
  • Maintenance
  • Frequency of Power cuts
     

Copyright © 2004-2005 Voyagerworld.net All right Reserved